Vedere la pagina 13
10 HDV100A3 Command & Response Manual-1306cr
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5104
Byte
Number
Byte
Value
Function
1 01 Start of frame
2 02 Number of control bytes
3 08 ID byte 08 = internal command
4 20 Function code 20 = stop time stamping
5 00 Number data bytes
6 2B Checksum
To resume time stamping send the following command:
Byte
Number
Byte
Value
Function
1 01 Start of frame
2 02 Number of control bytes
3 08 ID byte 08 = internal command
4 10 Function code 10 = resume time stamping
5 00 Number data bytes
6 1B Checksum
Time stamping will resume after reset.